Modbus Slave 安装包 , 无需积分
2021-11-19
Version 7.4.3
- BUG: Fixed an issue with license key validation.
2021-08-17
Version 7.4.2
- NEW: Print ASCII chars when Hex format is selected.
2021-06-16
Version 7.4.1
- BUG: Fixed an issue where exception code was not returned if number of registers > 125 when reading holding registers.
2021-05-27
Version 7.4.0
- NEW: Many new OLE/Automation functions.
2021-01-09
Version 7.3.1
- BUG: Fixed a windows placement problem. If a new window was opened on an extended display with
some different scale,layout or display resolution than the main display.
2020-05-10
Version 7.3.0
- NEW: Naming of single bits in binary display mode.
2020-04-20
Version 7.2.1
- NEW: If the user has switched from a dual monitor to a single monitor since we saved the
workspace, then ensure that main window is still visible on the single monitor.
- BUG: If a workspace file (*.msw) was dragged and dropped on the grid area, Modbus Slave terminated.
2020-04-16
Version 7.2.0
- NEW: Hex mode address input.
- NEW: Resize modbus window to fit grid size.
2020-03-26
Version 7.1.2
- BUG: Baud rate 256000 missing in enumeration.
2019-11-19
Version 7.1.1
- BUG: The obsolete OLE/Automation function Longs fixed.
2019-09-29
Version 7.1.0
- NEW: Baud rate 153600, 460800, 921600.
- NEW: Set decimal separator comma or dot to the user-default ANSI code page obtained from the operating system.
2018-05-26
Version 7.0.0
- NEW: 32 Bit unsigned int supported.
- NEW: 64 Bit signed and unsigned int supported.
- NEW: Display the Modbus address with the value in the cell.
2017-01-31
Version 6.2.0
- NEW: Timestamp in communication traffic.
- BUG: Using Modbus TCP/IP: Communication traffic showed false bytes if unit ID did not match.
Version 6.1.3
- BUG: Could not register Modbus Slave as COM control from C# and VB.
- BUG: Setting unsigned register from Excel for values > 32767
Version 6.1.2
- CHG: Save row height as in version 6.1.0. to support collapsed rows.
Version 6.1.1
- CHG: Fonts changed for support of high resolution monitors.
2015-10-26
Version 6.1.0
- NEW: Baud rate 230400
Version 6.0.3
- BUG: CRC error simulation did not work when RTU Over TCP/IP connection was used.
Version 6.0.2
- NEW: Context menu (Right click): Format menu items checked according to selected format.
- BUG: Multiple cell formatting could fail in some cell selection cases.
Version 6.0.1
- BUG: File open error.
2014-01-12
Version 6.0.0
- NEW: Format cells with individual data types.
- NEW: Improved automation interface. Control connection settings from Excel
and display Modbus values in Excel using Excel macro language VBA.
2013-11-17
Version 5.0.0
- NEW: Support of IPv6.
- NEW: Log function for communication traffic.
- NEW: Added a clear button in the traffic window.
- NEW: Most recently used IP Addresses in connection dialog.
- NEW: Modbus Slave remember its position. Ensure that Modbus Slave is still visible after
switching from a dual monitor to a single monitor.
Version 4.6.1
- NEW: Max number of windows extended to 100.
2012-03-10
Version 4.6.0
- NEW: Added display options: Byte swap for long, float and double.
Version 4.5.1
- BUG: The change "Only available serial ports are listed" in version 4.5.0 do not work with virtual ports.
2011-12-02
Version 4.5.0
- CHG: Only available serial ports are listed.
- NEW: Serial port number 1 - 255. Was 1 - 64.
- CHG: Unnecessary error code for setting serial port buffers removed. Problem with opening of serial port in rare cases.
- CHG: USB/232/485 converters using chip from FTDI with driver version 2.08.02 (August 11, 2010)
and newer:
The driver Detect error when application requests RTS_CONTROL_TOGGLE handshaking since
this is not supported in hardware. Modbus Poll could not open the serial port with this
driver.
- CHG: Change of quantity only do no more clear existing values.
Version 4.4.7
- BUG: Error Simulation: The "Return Exception 06. Busy" did not work as response for function 0x10.
- CHG: The function "Read/Write multiple registers" is no more restricted to a single window.
- CHG: Formatting of floating point numbers changed for better display of small numbers < 0 xss=removed> 2000.
Version 4.2.1
- CHG: TCP/IP connection. Error information improved.
- NEW: Possible to set the TCP server port. Was fixed to 502.
2007-05-18
Version 4.2.0
- NEW: Unicode support. Write any language in the alias cells.
- NEW: XP-themes.
- NEW: Save scroll bar position when save to file.
- NEW: Now you can set "Display Type" in the "Slave Definition" dialog box also.
- CHG: Help files now use html format.
- CHG: Display Binary is formatted as: 0000 0000 0000 0000. Was 0000000000000000.
2006-06-03
Version 4.1.0
- NEW: Error simulation:
- Insert random CRC errors
- Delayed response
- Skip response
- NEW: If a "*.mbs" file is located in the same directory as the workspace (*.msw) file
then the "*.mbp" file is stored as a relative file name in the *.msw. This allow
you to move the *.msw file with the *.mbp files to another directory. Thus The
*.mbw file will still be able to find the *.mbs files as they are relative to
the *.msw.
2006-06-03
Version 4.0.0
- NEW: Grid used to view Modbus values.
- NEW: Alt+S, Alt+U, Alt+H and Alt+B used to change display types.
- CHG: F8 used to display Poll definition instead of F2. (F2 used to edit cell)
Version 3.1.5
- NEW: Serial port 1-32. Was 1-8.
- NEW: Hyper link in about box.
- BUG: Double click a *.mbp file did not open Modbus Slave. This bug arose in V3.1.3
where Microsoft Visual C++ .NET 2003 compiler was used.
Read more: http://www.codeguru.com/cpp/w-d/doc_view/misc/article.php/c8549/
Version 3.1.4
- BUG: Max number of registers with the OLE/Automation was 127
should be 2048
Version 3.1.3
- BUG: Memory leak problem with the OLE/A 100+评论